Correcting errors

Correcting an error may require you to perform a specific set of actions. In some cases, the only available

corrective action is to replace the element.

Table 47

lists the element type codes assigned to the drive enclosure elements.

Table 47 Assigned element type codes

Code

Element

0.1.

Disk Drives

0.2.

Power Supplies

0.3.

Blowers

0.4.

Temperature Sensors

0.6

Audible Alarm

1

0.7.

EMU

0.C.

Controller OCP LCD

1

0.F.

Transceivers

1.0.

Language

1

1.1.

Communication Port

1

1.2.

Voltage Sensors

1.

Current Sensors

8.0

Drive Enclosure

1

8.2.

Drive Enclosure Backplane

8.7.

I/O Modules

1

Does not generate a condition report. However, for any error, you should record the error code. Then, implement the

recommended corrective action.

Drive conditions

The format of a disk drive condition report is 0.1.en.ec, where:

0.1. is the disk drive element type number

en. is the two-character disk drive element

ec is the error code

A direct correlation exists between the disk drive element number and the bay number. However, no

direct correlation exists between the disk drive

bay

number and the device Fibre Channel drive enclosure

physical address. The Fibre Channel drive enclosure physical address is assigned by negotiation

during system initialization.
The following sections define the disk drive error codes.

0.1.en.01 CRITICAL condition—Drive configuration or drive link rate

As each drive spins up and comes on-line, the EMU determines if the drive is Fibre Channel compatible

and can operate at the link rate (1 Gbps or 2 Gbps) established by the I/O module. If either of these

conditions are not met, the EMU issues the condition report 0.1.en.01.
The corrective actions for these conditions are:

When the drive is not Fibre Channel-compatible you must install a Fibre Channel compatible

drive or a drive blank.