Fault management displays, Displaying last fault information, Displaying detailed information – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 144

Advertising
background image

NOTE:

The major differences between the Event Display and the Termination Event display are:
• The Event display includes an EIP type field; it does not include a Code Flag field.
• The Event display includes a Corrective Action Code (CAC) field.
• The Termination Event display includes a Code Flag field; it does not include the EIP Type field.

Date

Time

SWCID

Evt No

CAC

EIP Type

Descrip-
tion

Figure 62 Typical HP Command View EVA Event display

The Event display provides the following information:

Date—The date the event occurred.

Time—The time the even occurred.

SWCID—Software Identification Code. A number in the range 1–256 that identifies the internal

firmware module affected.

Evt No—Event Number. A hexadecimal number in the range 0–FF that is the software component

identification number.

CAC—Corrective Action Code. A specific action to correct the problem.

EIP Type—Event Information Packet Type. A hexadecimal character that defines the event

information format.

Description—The problem that generated the event.

Fault management displays

When you do not have access to the GUI, you can display and analyze termination codes (TCs) on the

OCP LCD display. You can then use the event text code document, as described in the section titled

“Interpreting Fault Management Information” to determine and implement corrective action. You can

also provide this information to the authorized service representative should you require additional

support. This lets the service representative identify the tools and components required to correct the

condition in the shortest possible time.
When the fault management display is active, you can either display the last fault or display detailed

information about the last 32 faults reported.

Displaying Last Fault Information

Complete the following procedure to display Last Fault information

1.

When the Fault Management display is active, press

to select the Last Fault menu.

2.

Press

to display the last fault information.

The first line of the TC display contains the eight-character TC error code and the two-character IDX

(index) code. The IDX is a reference to the location in the TC array that contains this error. The

second line of the TC display identifies the affected parameter with a two-character parameter

number (0–30), the eight-character parameter code affected, and the parameter code number.

3.

Press

to return to the Last Fault menu.

Displaying Detailed Information

The Detail View menu lets you examine detailed fault information stored in the Last Termination Event

Array (LTEA). This array stores information for the last 32 termination events.
Complete the following procedure to display the LTEA information about any of the last 32 termination

events:

144

Controller fault management

Advertising