Table 20 Fibre Channel switch basic troubleshooting

Problem

Recommended action

SFPs are installed in ports but no

indicators are lit.

1. Verify that the power cord is firmly seated in the switch and

is connected to the power outlet.2. Check the power indicator

to verify that the switch is on.

SFP is installed, but the Port Bypassed

indicator is lit.

Re-seat the SFP. If the same condition occurs, the SFP is probably

faulty and should be replaced.

SFP is installed, but the SFP status

indicator and the Port Bypassed indicator

are lit.

This condition indicates that the switch is not receiving a valid

Fibre Channel signal or that the switch is receiving an LIP.1. Ensure

that the switch is powered on.2. Contact your HP authorized

service representative for further assistance.

SFP is installed and the SFP status

indicator is lit, but the devices are not

communicating.

This condition indicates that the switch is receiving a valid Fibre

Channel signal, but there are no upper level protocols active.1.

Verify that you are running the correct firmware on all storage

system hardware.2. Check the Loop Operational indicator.a. If

the Loop Operational indicator is lit, the devices have completed

initialization.b. If the Loop Operational indicator is off, the devices

were not initialized. Disconnect the devices from the switch.

Reconnect the devices one at a time. This allows you to isolate

the device that is responsible for the loop failure.3. Contact your

authorized service representative for further assistance.

HSV controllers

This section describes the major features, purpose, and function of the HSV210 and HSV200 controllers.

Each Enterprise Virtual Array has a pair of these controllers.

Figure 23

shows the HSV210 controller rear

view.

Figure 24

shows the HSV200 controller rear view. The front view of both controllers is shown in

Figure 25

.

1

2

3

4

8

5

6

7

5

6

10

9

Figure 23 HSV210 controller—rear view

1. Dual controller interconnect

2. CAB (cabinet address bus)

3. Unit ID

4. Power ON switch

5. FC device ports

6. FC cache mirror ports

7. FC host ports

8. Power supply 0

9. Power supply 1

10. Service connectors (not for customer use)