Direct connect, 4 eva4000/6000 configuration – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 28

Advertising
background image

Browser

Host X

FCA

Management

Server

Command

View EVA

CXO8055D

Controller

A

FCA

FCA

FCA

Host Z

Browser

Non-Host

FP1

FP2

Loop
Pair 1

Loop
Pair 1

Controller

B

FP1

FP2

Network Interconnection

Drive Enclosures

FP = Fibre (Host) Port
FCA = Fibre Channel Adapter

Cache

Mirror Ports

B

A

B

A

Fabric 1

Fabric 2

Figure 4 EVA4000/6000 configuration

Direct connect

NOTE:

Direct connect is currently supported on Microsoft Windows only. Refer to the

HP StorageWorks

Enterprise Virtual Array 4000/6000/8000 release notes

for more information on direct connect support.

Direct connect provides a lower cost solution for smaller configurations. When using direct connect, the

storage system controllers are connected directly to the host(s), not to SAN Fibre Channel switches. Make

sure the following requirements are met when configuring your environment for direct connect:

A Windows host running HP Command View EVA must be connected to one port on each EVA

controller. The management host must use dual HBAs for redundancy.

To provide redundancy, it is recommended that dual HBAs be used for each additional host

connected to the storage system. Using this configuration, up to four hosts (including the

management host) can be connected to an EVA8000, and up to two hosts can be connected to

an EVA6000 or EVA4000.

The Host Port Configuration must be set to Direct Connect using the OCP.

HP Continuous Access cannot be used with direct connect configurations.

28

Enterprise Virtual Array startup

Advertising