Cmu_add_logical_group(8), Name, Synopsis – HP Insight Cluster Management Utility User Manual

Page 178: Description, Options, Examples

Advertising
background image

cmu_add_logical_group(8)

NAME

cmu_add_logical_group -- Add logical groups.

SYNOPSIS

# /opt/cmu/bin/cmu_add_logical_group

<-n | -i | -f filename | -s>

# /opt/cmu/bin/cmu_add_logical_group

<-n name -d devicename>

# /opt/cmu/bin/cmu_add_logical_group

<-n name -d diskless -I golden_node_ip

-k kernel_version>

DESCRIPTION

Add HP Insight CMU logical groups.

OPTIONS

-h|--help

show help

-s|--help-file-syntax

show help for file syntax

-i|--interactive

specify logical group(s) information is provided interactively

-f|--filename inputfile

input logical group(s) from inputfile

-n|--name

logical group name

-d|--device

device name (e.g. cciss/c0d0 or diskless)

(diskless only) -k|--kernel

kernel version (e.g. 2.6.18-194.el5)

(diskless only) -I|--goldenip

golden_node_ip

EXAMPLES

To create the logical group "test" with device "cciss/c0d0":

# /opt/cmu/bin/cmu_add_logical_group -n test -d cciss/c0d0

To create a list of logical groups from file logical_group_file:

# /opt/cmu/bin/cmu_add_logical_group -f logical_group_file

To create a diskless logical group from golden node IP address 1.2.3.4 running kernel version
2.6.18-194.el5:

# /opt/cmu/bin/cmu_add_logical_group -n dl_group -d diskless -I 1.2.3.4

-k 2.6.18-194.el5

178

Advertising