Storage system mapping – HP 3PAR Application Software Suite for VMware User Manual

Page 39

Advertising
background image

Figure 22 Host Explorer Configuration Option

The selections available from Host Explorer Configuration screen are described in

Table 3 (page 39)

.

Table 3 Host Explorer Configuration Option Fields

Description

Field

Starts the Host Explorer service.

Start Service

Stops the Host Explorer service.

Stop Service

Refreshes/restarts the Host Explorer service.

Refresh Service

Allows you to change the refresh interval that determines how frequently the host explorer
service checks for host changes. The current state is compared with the previous state

Change Refresh Interval

and, if there have been any changes, the HP 3PAR Storage System is updated. The
default refresh interval is set to 12 hrs.

Indicates whether the HP 3PAR Host Explorer service is currently running.

Status

NOTE:

The Host Explorer Service needs to be restarted after changing the refresh interval time.

Storage System Mapping

The Storage System Mapping option is used to map existing HP 3PAR Storage System credentials
to be used by Host Explorer for submitting corresponding ESX host information. The credentials
need to be created via Storage System Credential or RMVMware.exe with option VCenterRegister
prior to the mapping. Since Host Explorer uses the system ID obtained from ESX host information
to determine which HP 3PAR Storage System it is connected to, only one mapping is allowed per
storage system. The Host Explorer Storage System Mapping option appears (

Figure 23 (page 40)

).

Host Explorer Tab

39