HP Compaq StorageWorks TL881 DLT Mini-Library User Manual
Page 103

3-34 Compaq TL881 Minilibrary System Users Guide
8.
Press the
Enter
button. When the Special Configuration Submenu
reappears, turn the power switch off to recycle power.
NOTE: Expansion Unit installation remaps the cartridge slot numbering system as follows:
The 16-slots of the Expansion Unit become slot numbers 0-15. Slots 0-9 of the first
MiniLibrary Base Module become slots 16-25, etc.
A Configuration Example - Setting the SCSI ID
1.
Turn the system on, and wait until the Power-On Self Test terminates
and the default screen appears on the display. Figure 3-25 shows a
typical default screen. Yours may vary depending on the number of
modules in your system, as shown in the second line.
SHR-1446
Figure 3-25. Default Screen
2.
At the Default Screen, press the
Enter
button. The display will show the
Main Menu as shown in Figure 3-26:
SHR-1331
Figure 3-26. Main Menu
3.
Press the
button three times to move the
to Configure Menu, then
press the
Enter
button. The display will show the Configure Submenu,
as shown in Figure 3-27. Note that the
at the end of the fourth line
means that there are additional configuration options that can be reached
by scrolling with the
button.