Diagnosing array problems, Controller board runtime leds – HP Smart Array P700m Controller User Manual
Page 27

Diagnosing array problems 27
Diagnosing array problems
Controller board runtime LEDs
Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a
predetermined pattern as part of the POST sequence. At all other times during server operation, the
illumination pattern of the runtime LEDs indicates the status of the controller, as described in the following
table.
LED ID
Color
LED name and interpretation
1
Amber
CR10: Thermal Alert LED. Not used on this controller.
2
Amber
CR9: System Error LED. The controller ASIC has locked up and cannot process
any commands.
3
Amber
CR1: Diagnostics Error LED. One of the diagnostics utilities in the server has
detected a controller error.
4
Amber
CR2: Drive Failure LED. A physical drive connected to the controller has failed.
Check the Fault LED on each drive to determine which drive has failed.
5
Green
CR3: Activity LED for port 2.
6
Green
CR4: Activity LED for port 1.
7
Green
CR5: Command Outstanding LED. The controller is working on a command from
the host driver.
8
Green
CR6: Controller Heartbeat LED. This LED flashes every 2 seconds to indicate the
controller health.
9
Green
CR7: Gas Pedal LED. This LED, together with the Idle Task LED, indicates the
amount of controller CPU activity. For details, see the following table.