Overview of the installation procedure 7

Overview of the installation procedure

Installing the controller in an unconfigured server

blade

New HP ProLiant server models autoconfigure when they are powered up for the first time. For more

information about the autoconfiguration process, see the server-specific setup and installation guide or the

HP ROM-Based Setup Utility User Guide. These guides are available on the server Documentation CD.

IMPORTANT:

Do not power up the server until the hardware configuration is satisfactory, as

described in the procedure given in this section.

To install the controller in an unconfigured server blade:

1.

Install the controller hardware in the server blade.

2.

Install the server blade in a blade enclosure.

3.

Install an HP 3Gb SAS BL-c Pass-Thru Module in the blade enclosure.

4.

Connect the server blade to the pass-thru module.

5.

Connect the pass-thru module to a drive enclosure.

6.

If necessary, install physical drives in the drive enclosure.
The number of drives connected to the pass-thru module determines the RAID level that is
autoconfigured when the server is powered up. For details, see the server-specific setup and

installation guide or the HP ROM-Based Setup Utility User Guide.

7.

Power up the server. The autoconfiguration process runs.

8.

Update the server firmware ("

Methods for updating the firmware

" on page

10

).

9.

Update the controller firmware ("

Methods for updating the firmware

" on page

10

).

10.

Install the operating system and device drivers ("

Installing device drivers

" on page

14

). Instructions

are provided with the CD that is supplied in the controller kit.

11.

(Optional) Create additional logical drives ("

Configuring an array

" on page

11

).

The server is now ready to use.

Installing the controller in a previously-configured

server

1.

Back up data on the system.

2.

Update the server blade firmware ("

Methods for updating the firmware

" on page

10

).

3.

If the new controller will be the boot device, install the device drivers ("

Installing device drivers

" on

page

14

). Otherwise, go directly to step 4.

Advertising