HP 6400.8400 Enterprise Virtual Array User Manual

Page 102

Advertising
background image

Table 22 Error Messages (continued)

How to Correct

Meaning

Status Code Value

Report the error to product support.

The storage system time is not set. The
storage system time is set automatically by
the management software.

39
Time Not Set

Report the error to product support.

The requested operation is not supported by
this firmware version. This can indicate a
user or program error.

40
Not a Supported Version

Report the error to product support.

The specified SCVD does not have a logical
disk associated with it. This can indicate a
user or program error.

41
No Logical Disk for Vdisk

Delete the associated presentation(s)
and retry the request.

The virtual disk specified is already
presented to the client and the requested
operation is not allowed.

42
Logical disk Presented

Report the error to product support.

The request is not allowed on the slave
controller. This can indicate a user or
program error.

43
Operation Denied On Slave

Report the error to product support.

This error is no longer supported.

44
Not licensed for data replication

Configure the virtual disk to be a
member of a Continuous Access group
and retry the request.

The operation cannot be performed because
the virtual disk is not a member of a
Continuous Access group.

45
Not DR group member

Configure the Continuous Access
group correctly and retry the request.

The operation cannot be performed because
the Continuous Access group is not in the
required mode.

46
Invalid DR mode

Wait for the copying state to complete
and retry the request.

The operation cannot be performed because
at least one of the virtual disk members is in
a copying state.

47
The target DR member is in full
copy, operation rejected

Use the management software to save
the password specified so
communication can proceed.

The management software is unable to log
in to the storage system. The storage system
password has been configured.

48
Security credentials needed.
Please update your system's ID
and password in the Storage
System Access menu.

Use the management software to set
the password to match the device so
communication can proceed.

The management software is unable to login
to the device. The storage system password
may have been re-configured or removed.

49
Security credentials supplied
were invalid. Please update your
system's ID and password in the
Storage System Access menu.

No action required.

The management software is already logged
in to the device. (This message is
informational only.)

50
Security credentials supplied
were invalid. Please update your
system's ID and password in the
Storage System Access menu.

Verify that devices are powered on
and that device hardware connections
are functioning correctly.

The Continuous Access group is not
functioning.
.

51
Storage system connection down

Add one or more virtual disks as
members and retry the request.

No virtual disks are members of the
Continuous Access group.

52
DR group empty

Retry the request with valid attributes
for the operation.

The request cannot be performed because
one or more of the attributes specified is
incompatible.

53
Incompatible attribute

Remove the virtual disk as a member
of a data replication group and retry
the request.

The requested operation cannot be
performed on a virtual disk that is already
a member of a data replication group.

54
Vdisk is a DR group member

102 Error messages

Advertising