Limitations, Failure scenarios, Hp-ux – HP 6400.8400 Enterprise Virtual Array User Manual
Page 131

Limitations
•
HP P6000 Continuous Access is not supported with single path configurations.
•
Single path HBA server is not part of a cluster.
•
Booting from the SAN is supported on single path HBA servers.
Figure 41 VMware configuration
5 SAN switch 1
1 Network interconnection
6 SAN switch 2
2 Single HBA server
7 Controller A
3 Dual HBA server
8 Controller B
4 Management server
Failure scenarios
HP-UX
Table 30 HP-UX failure scenarios
Failure effect
Fault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.
Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller restart
Failure scenarios
131