Table 10 Failback preference behavior (continued)

Behavior

Point in time

Setting

If cache data for a LUN exists on a particular
controller, the unit will be brought online there.

On dual boot or controller resynch

Otherwise, the units are brought online to
Controller B.

All LUNs are brought online to the surviving
controller.

On controller failover

All LUNs remain on the surviving controller.
After controller restoration, the units that are

On controller failback

online to Controller A and set to Path B are
brought online to Controller B. This is a one
time occurrence. If the host then moves the LUN
using SCSI commands, the LUN will remain
where moved.

Table 11 (page 38)

describes the failback default behavior and supported settings when

ALUA-compliant multipath software is running with each operating system. Recommended settings
may vary depending on your configuration or environment.

Table 11 Failback settings by operating system

Supported settings

Default behavior

Operating system

No Preference
Path A/B – Failover Only

Host follows the unit

1

HP-UX

Path A/B – Failover/Failback

No Preference
Path A/B – Failover Only

Host follows the unit

1

IBM AIX

Path A/B – Failover/Failback

No Preference
Path A/B – Failover Only

Host follows the unit

1

Linux

Path A/B – Failover/Failback

No Preference

Host follows the unit

OpenVMS

Path A/B – Failover Only

Path A/B – Failover/Failback
(recommended)

No Preference

Host follows the unit

1

Sun Solaris

Path A/B – Failover Only

Path A/B – Failover/Failback

No Preference

Host follows the unit

Tru64 UNIX

Path A/B – Failover Only

Path A/B – Failover/Failback
(recommended)

No Preference
Path A/B – Failover Only

Host follows the unit

1

VMware

Path A/B – Failover/Failback

No Preference

Failback performed on the host

Windows

Path A/B – Failover Only

Path A/B – Failover/Failback

38