Recognizing hard drive failure – HP D6000 Disk Enclosure User Manual

Page 30

Advertising
background image

Troubleshooting 30

Status code

Action

9 = Standby heartbeat

failure

Replace the I/O module that has an amber LED. If no I/O module has an amber LED,

replace one I/O module, and then wait 30 seconds. If the GSI LED is still amber,

replace the other I/O module. AC power cycle the D6000. If replacing the I/O

modules does not resolve the issue, replace the drawer.

10 = Remote I/O

module heartbeat
failure

Replace the I/O module that has an amber LED. If no I/O module has an amber LED,

replace one I/O module, and then wait 30 seconds. If the GSI LED is still amber,

replace the other I/O module. AC power cycle the D6000. If replacing the I/O
modules does not resolve the issue, replace the drawer.

11 = Enclosure thermal

shutdown imminent

Check for thermal issues within the D6000 drawer, such as extremely hot drives, air

blockages, missing or failed fans, or high ambient temperature.

12 = Enclosure thermal
shutdown occurred

Check for thermal issues within the D6000 drawer, such as extremely hot drives, air

blockages, missing or failed fans, or high ambient temperature.

13 = Enclosure

management bus
failure; false fan failures

may occur

Replace all I/O modules in the D6000 drawer. If replacing the I/O modules does not

resolve the issue, replace the entire drawer.

14 = Signal integrity

errors detected

Replace the SAS I/O cables. If replacing the cables does not resolve the issue, replace

the I/O module showing the signal integrity issues. If replacing the I/O modules does

not resolve the issue, replace the drawer.

15 = Power supply PIC
communications error

Verify that, if a power supply does not have a green LED illuminated, that it is
correctly cabled to a power source. This warning can also be caused by a failed power

supply from either of the D6000 storage drawers. If the cabling and the power source

are ok, troubleshoot by replacing each power supply in turn. If replacing the power
supplies does not resolve the issue, power off the D6000 and remove all sources of AC

power to ensure that all power is removed from the D6000. After the power/standby

LED goes completely off, wait a few minutes and then power on the D6000. If power
cycling does not resolve the issue, replace IO modules in the D6000 drawer. If the

issue persists, replace the entire drawer.

16 = Unsupported
backplane detected

The I/O module is not supported for use in the enclosure. Remove the installed I/O

module and replace with the I/O modules designed for use with the D6000.

* I/O module firmware and power block firmware are delivered through the D6000 download process.

Recognizing hard drive failure

When troubleshooting drive problems, first confirm that the drives are supported for use in the D6000. For

more information, see the QuickSpecs on the HP website (

http://www.hp.com/go/d6000/quickspecs

).

In an HP D6000, a steadily glowing Fault LED indicates that the drive has failed.
Other indications of failed hard drives:

ACU represents failed drives with a distinctive icon.

HP SIM can detect failed drives remotely across a network. (For more information about HP SIM, refer

to the documentation on the Management CD.)

ADU lists all failed drives.

CPQONLIN identifies failed drives in a NetWare environment.

For additional information about diagnosing hard drive problems, see the HP ProLiant Servers

Troubleshooting Guide.