background image

Component identification 9

Item

Description

Status

2

Internal Health LED

Green = System health is good.

Off = System is off.

3

GSI LED*

Amber = Enclosure requires service
check: I/O, fan and power supply LEDs,

and AC power cables to power supplies.

Off = Enclosure is functioning normally.

4

UID button/LED (Drawer 2) Blue = UID LED is enabled from the UID

button.

Blue flashing = System is in hard drive

locate mode or an enclosure firmware
update is in progress.

Off = UID LED is disabled.

5

Power supply LED

Green = Power on and power supply
functioning properly

Off = One or more of the following

conditions exists:

System powered off

AC power unavailable

Power supply failed

Power supply exceeded current limit

6

System fan LED

Green = Normal operation

Amber flashing = Fault
Off = Fan unseated from connector or

failed

7

I/O module LED

Green = System activity

Amber = Fault
Off = Enclosure is powered off.

8

7-segment display*

1 = SES overall warning

2 = Temperature sensor warning

3 = Cooling fan warning
4 = Power supply warning

5 = Host GSI enabled

6 = I/O PIC upgrade needed
7 = Power supply PIC upgrade needed

8 = CPLD upgrade needed

9 = Standby heartbeat failure
10 = Remote I/O module heartbeat

failure

11 = Enclosure thermal shutdown
imminent

12 = Enclosure thermal shutdown

occurred
13 = Enclosure management bus failure,

false fan failures may occur

14 = Signal integrity errors detected

15 = Power supply PIC communications
error

16 = Unsupported backplane detected

9

UID button/LED (Drawer 1) Blue = UID LED is enabled from the UID

button.

Blue flashing = System is in hard drive

locate mode or an enclosure firmware
update is in progress.