Cutout for double ovens (2 thermal ovens), Cutout for installation over a warming drawer – GE 30 Electric Built-In Wall Ovens User Manual

Page 3

Advertising
background image

2 C

CUTOUT FOR DOUBLE OVENS (2 THERMAL OVENS)

NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim

both sides equally to establish the cutout width.

Dim.

Description

27” Double Oven

30” Double Oven with

Pedestal

30” Double Oven

without Pedestal

A

Cabinet Width

27” (68.6 cm)

30” (76.2 cm)

30” (76.2 cm)

B

Cutout Width

25” (63.5 cm) min.

25

1

ø

4

” (64.1 cm) max.

28

1

ø

2

” (72.4 cm) min.

28

5

ø

8

” (72.7 cm) max.

28

1

ø

2

” (72.4 cm) min.

28

5

ø

8

” (72.7 cm) max.

C

Cutout Height

49

11

ø

16

” (126.2 cm) min.

50

1

ø

8

” (127.3 cm) max.

51

13

ø

16

” (131.6 cm) min.

51

15

ø

16

” (131.9 cm) max.

50 ¼” (127.64cm)

D

Overlap of Oven

Over Side Edges

of Cutout

1” (2.5 cm)

11

ø

16

” (1.75 cm)

11

ø

16

” (1.75 cm)

E

Clearance to

Adjacent Corners,

Drawers, Walls, etc.,

When Door Is Open

23” (50.8 cm) min.

23” (53.3 cm) min.

23” (53.3 cm) min.

F

Overlap of Oven

Top of Cutout

1” (2.5 cm) min.

1” (2.5 cm) min.

(1

1

ø

4

” (3.2 cm) for PT9550)

1” (2.5 cm) min.

(1

1

ø

4

” (3.2 cm) for PT9550)

G

Overlap of Oven

Bottom of Cutout

1” (2.5 cm) min.

1

1

ø

4

” (3.2 cm)

1

1

ø

4

” (3.2 cm)

H

Junction Box

Location

8

3

ø

4

” (22.2 cm) max.

right side only

9

1

ø

2

” (24.1 cm) max.

right side only

9

1

ø

2

” (24.1 cm) max.

right side only

J

Height to Bottom

of Junction Box

44” (111.8 cm)

47” (119.4 cm)

47” (119.4 cm)

K

Recommended

Cutout Location

from Floor

13

1

ø

4

” (33.7 cm)

12” (30.5 cm)

12” (30.5 cm)

31-10958-1

11-13 GE

2 D

CUTOUT FOR INSTALLATION OVER A WARMING DRAWER

NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports

above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly

grounded receptacle must be installed. Refer to installation instructions packed with

the Warming Drawer for specific installation requirements.

Anti-Tip Block Against

Rear Wall Per Warming

Drawer Requirement

2" (5.1 cm)

Min.

Per Warming

Drawer

Requirement

Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.

Continue to Section 3.

H

B

C

K

F

G

D

A

J

E

Junction

Box

Location

(junction

box may

be located

in adjacent

cabinet)

Cutout Depth

23-1/2”

(59.7 cm) Min.

Advertising