Advance Planning

ADVANCE PLANNING

Ductwork Planning
• These vent hoods are equipped for 10" round ductwork.

For best performance, use 10" round ductwork on the
48" wide hoods. 30" and 36" hoods may be transitioned
to 8" round.

• This hood may be vented vertically through upper

FDELQHWVVRI¿WRUFHLOLQJ$GXFWWUDQVLWLRQSLHFHLV

supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For

satisfactory performance, duct run should not exceed
IWHTXLYDOHQWOHQJWKIRUDQ\GXFWFRQ¿JXUDWLRQV

• Refer to “Duct Fittings” chart to compute the maximum

permissible length for duct runs to the outdoors.

• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior

opening. Order the wall or roof cap and any transition
needed in advance.

• When applicable, install any makeup (replacement)

air system in accordance with local building code
requirements. Visit GEAppliances.com for available
makeup air solutions.

Wall Framing for Adequate Support
• These vent hoods are heavy. Adequate structural

support must be provided. Hoods must be secured to
vertical studs in the wall.

• It is strongly recommend that the vent hood with duct

FRYHUEHRQVLWHEHIRUH¿QDOIUDPLQJDQGZDOO¿QLVKLQJ

This will also help to accurately locate the ductwork and
electrical service.

Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available
WR¿WDOOPRGHOV7KHGXFWFRYHUFRQFHDOVWKHGXFWZRUN
UXQQLQJIURPWKHWRSRIWKHKRRGWRWKHFHLOLQJRUVRI¿W

Stack one or more duct covers over the top of the hood
to reach your ceiling height.

POWER SUPPLY

IMPORTANT - (Please read carefully)

WARNING

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.

AVERTISSEMENT

POUR DES

RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE
CORRECTEMENT MIS À LA TERRE.

Remove house fuse or open circuit breaker before
beginning installation.

Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing
local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker
or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above

requirements, call a licensed electrician before
proceeding.

• Route house wiring as close to the installation location

as possible on the back wall or ceiling.

• Connect the wiring to the house wiring in accordance

with local codes.

Grounding instructions

The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.

WARNING

The improper connection of

the equipment-grounding conductor can result in a risk
RIHOHFWULFVKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRU

service representative if you are in doubt whether the
appliance is properly grounded.

AVERTISSEMENT

/HPDXYDLVEUDQFKHPHQWGX¿OGHPLVHjODWHUUHSHXW

causer un choc électrique. En cas de doute, consulter un
pOHFWULFLHQTXDOL¿pRXXQWHFKQLFLHQSRXUGpWHUPLQHUVL

l’appareil est à la terre.