Advance planning, Duct fittings – GE ZV48SSFSS User Manual

Page 8

Advertising
background image

8

49-80151-8

Advance Planning

DUCT FITTINGS

Equivalent

Quantity

Total

Duct Piece

Length*

Used

Length

10" round

to 8" round

5 ft.

Round,

1 ft.

straight

(per foot length)

3-1/4" x 10"

1 ft.

3-1/4" x 12" straight

(per foot length)


8" Dia. 17 ft.

90° elbow

10" Dia. 24 ft.

8" Dia. 10 ft.

45° elbow

10" Dia. 14 ft.

3-1¦4" x 12"

15 ft.

3-1/4" x 10"

14 ft.

90° elbow

3-1/4" x 10"

8 ft.

3-1/4" x 12"

9 ft.

45° elbow

3-1/4" x 10"

33 ft.

3-1/4" x 12"

36 ft.

 

ƒÀDWHOERZ

10" round transition

to 3-1/4" x 10" or

3-1/4" x 12"

9 ft.

3-1/4" x 10" or

3-1/4" x 12" to

10" round transition

6 ft.

10" round to 3-1/4" x 10"

16 ft.

3-1/4" x 12" transition

13 ft.

90° elbow

3-1/4" x 10"

9 ft.

3-1/4" x 12" to 10" round

8 ft.

transition 90° elbow

Round

8" Dia. 32 ft.

wall cap

10" Dia. 41 ft.

with damper

3-1/4" x 10"

24 ft.

3-1/4" x 12" wall cap

26 ft.

with damper


Round

8" Dia. 44 ft.

roof cap

10" Dia. 56 ft.

Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.

Note: Do not exceed maximum permissable
equivalent lengths!

Maximum recommended duct
OHQJWKIRUWKHVHKRRGVIHHW

Flexible ducting:
,IÀH[LEOHPHWDOGXFWLQJLVXVHGDOO

the equivalent feet values in the table
VKRXOGEHGRXEOHG7KHÀH[LEOHPHWDO

duct should be straight and smooth
and extended as much as possible.

'R127XVHÀH[LEOHSODVWLFGXFWLQJ

Total Duct Run

Note:

Any home ventilation system, such as a

YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUÀRZRI
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\¿UHSODFHV
JDVIXUQDFHVJDVZDWHUKHDWHUVDQGRWKHU
naturally vented systems. To minimize the chance
RILQWHUUXSWLRQRIVXFKQDWXUDOO\YHQWHGV\VWHPV
IROORZWKHKHDWLQJHTXLSPHQWPDQXIDFWXUHU·V
JXLGHOLQHVDQGVDIHW\VWDQGDUGVVXFKDVWKRVH
published by NFPA and ASHRAE. When applicable,
install any makeup (replacement) air system in
DFFRUGDQFHZLWKORFDOEXLOGLQJFRGHUHTXLUHPHQWV
Visit GEAppliances.comIRUDYDLODEOHPDNHXSDLU
solutions.

*Actual length of straight duct plus duct

¿WWLQJHTXLYDOHQW(TXLYDOHQWOHQJWKRIGXFWSLHFHV
are based on actual tests conducted
E\*((YDOXDWLRQ(QJLQHHULQJDQGUHÀHFW
requirements for good venting performance with any
ventilation hood.

Hoods Are Equipped

)RU5RXQG'XFW

* Hoods are supplied with a 10"

round transition. A locally
supplied transition is required
for other sizes.

Note: Outlet on top of hood is

8-1/8" x 8".