MultiModemISDN User Guide

S-Register: S5
Function:

Backspace Character

Unit:

Decimal ASCII code

Range:

0–32, 127

Default:

8 (^H)

Description: Specifies the character used by the TA to delete the previous character in the

command line.

S-Register: S7
Function:

Wait for Connection (Abort Timer)

Unit:

1 second

Range:

0–255

Default:

45

Description: Sets the Abort Timer delay time, which is the length of time the TA waits for a

connection after dialing. If no connection is established during the specified
time, the TA ends the call.

S-Register: S8
Function:

Pause Time for Comma

Unit:

1 second

Range:

n=0-255

Default:

2 (2 seconds)

Description: S8 sets the length of the pause caused by a comma inserted in a dialing

command. The default setting is 2 seconds, where each unit is one second.
S8 may be set for up to 255 seconds.

S-Register: S10
Function:

DCD Drop Time

Unit:

50 ms

Range:

0–254, 255

Default:

20

Description: Sets the time after a carrier signal is lost before the TA disconnects. (The

&C2 command must be in effect.) Default setting is one second. Maximum
delay is 25.4 seconds (S10=254). Set S10 to 255 to cause the TA not to
disconnect with loss of carrier.

S-Register: S25
Function:

DTR Drop Time

Unit:

100 ms

Range:

0, 1–255

Default:

5

Description: Sets the time that DTR must remain low before TA disconnects. The S25 unit

value for 0 is 50 ms. For values from 1 through 255, the unit value is 100 ms.