Maintenance, Section i, Operator maintenance – EOTech M914 (AN/PVS-14) Monocular Night Vision Device User Manual

Page 41: 1 troubleshooting procedures, Chapter 3 -1, Maintenance -1, Section i -1, Operator maintenance -1, 1 troubleshooting procedures -1, Table 3-1 troubleshooting procedures

Advertising
background image

3-1

CHAPTER 3

MAINTENANCE

SECTION I

OPERATOR MAINTENANCE


3.1 TROUBLESHOOTING PROCEDURES

The procedures below will help correct some of the basic
problems that may arise with the MNVD. If the equipment
malfunction is not listed, or the actions listed do not correct
the fault, refer to section 3.4 for additional guidance.

Table 3-1 Troubleshooting Procedures

Malfunction

Probable Cause

Corrective Action

1. No image is

present when

turning on the

MNVD.

a. Batteries are improperly

installed.

a. Verify batteries are properly

installed per section 2.2, Battery

Installation.

b. Battery power is low.

b. Replace batteries per section

2.2, Battery Installation.

c. Battery contacts require

cleaning.

c. Clean battery contacts per

section 3.2, Battery Compartment

and Battery Cap.

2. Image abruptly

turns off when in

ON or IR modes.

a. High light shutdown has

been initiated.

a. Reset (power on) the MNVD

per section 2.6. Install the

objective lens cover per section

2.5, Objective Lens Cover, if

necessary.

3. Poor or

degraded image.

a. Lens cover installed

(dark ambient conditions).

a. Remove lens cover per section

2.4, Objective Lens Cover.

b. Lens cover not installed

(bright ambient conditions).

b. Install lens cover per section

2.5, Objective Lens Cover.


Advertising