Installation, Aux terminals – Outback Power Systems FLEXmax Extreme Owners Manual User Manual

Page 19

Advertising
background image

Installation

900-0150-01-00 Rev A

17

AUX Terminals

The AUX (Auxiliary) output is a small power supply that provides a 12 Vdc output current to an isolated load. The
AUX output can respond to many criteria and control many functions. These include cooling fans, vent fans,
load diversion, fault alarms, and automatic generator control. The AUX can only control one function at a time.

Terminals

and

are the + and – terminals for the AUX output. These terminals are colored gray (–) and

brown (+) for easy reference. The terminals can supply up to 250 mA at 12 Vdc (3 W). The AUX circuit contains
electronic overcurrent protection, which resets after being overloaded. No additional fuses are required for the
AUX terminals.

The AUX LED illuminates when the output becomes active. (See page 23 for an illustration of LED indicators.)

Figure 13

AUX Vent Fan

Figure 14

AUX Diversion Control

In this example, the AUX output directly drives a
12-volt vent fan. The – and + wires on the fan are

connected to terminals

and

, the AUX– and

AUX+ terminals

.

In this example, the AUX output drives a relay that
diverts wind power. The relay’s coil is connected to

terminals

and

, the AUX+ and AUX–

terminals. When the AUX output closes the relay
(based on battery voltage), the relay diverts excess
power to a water heating element.

Relay

Element

Turbine

NOTE: Relays and elements shown are examples only and may
vary depending on the installation.

Advertising