Specifications, Electrical and mechanical specifications, Environmental specifications – Outback Power Systems FLEXmax Extreme Owners Manual User Manual

Page 65

Advertising
background image

900-0150-01-00 Rev A

63

Specifications

Electrical and Mechanical Specifications

Table 8

Electrical and Mechanical Specifications for Model FM Extreme-150VDC

Specification Value

Maximum Continuous Output Current

80 amps

Maximum Input Current (short-circuit)

64 amps

Nominal Battery System Voltage

12, 24, 36, 48 or 60 Vdc (adjustable)

PV Open-Circuit Voltage

145 Vdc temperature corrected V

oc

(operational maximum)

Operating Voltage Range

Low

10.5 Vdc (lowest battery voltage for functionality)

High

150 Vdc (highest open-circuit voltage before equipment damage)

Standby Power Consumption

Less than 1 watt typical

Charge Cycle

Three-stage

Minimum Battery Bank Size

100 Ah

Charging (Output) Range

13 to 80 Vdc

Temperature Compensation

Adjustable from 2 mV/cell/°C to 6 mV/cell/°C

Remote Interface

RJ45 modular connector (CAT 5 8-wire cable)

Conduit Openings

Front, rear, sides (plugs inserted)

Dimensions (H x W x D)

18.56” x 8.8” x 6.0” (47.1 cm x 20.9 cm x 15.2 cm)

Shipping Dimensions (D x W X L)

9.69” x 11.75” x 22.0” (24.6 cm x 29.8 cm x 55.9 cm)

Weight

21.0 lb (9.5 kg)

Shipping Weight

21.5 lb (9.7 kg)

Environmental Specifications

Table 9

Environmental Specifications for Model FM Extreme-150VDC

Specification Value

Operating Temperature Range

Ambient -20°C to 45°C (-4°F to 113°F)

Output Power Temperature Derating

Ambient 45°C to 60°C (113°F to 140°F)

Ingress Protection Rating

IP 54

Enclosure Type

NEMA 3R

Maximum Altitude Rating

10,000 ft

Advertising