Wixey WR550 REMOTE PLANER READOUT User Manual

Page 7

Advertising
background image

7


Loses calibration

• Make sure that your machine is properly grounded.
• Route the cable away from electric motors or other electrical controls.
• Check for dirt on the scale or inside the sensor. Remove and clean if needed.
• Check for static discharges from a nearby dust collector or other source

Note: If a static discharge from your finger zaps the readout or a nearby dust collector
happens to zap your machine it can cause this error. Make sure the dust collector is properly
grounded and the dust port on your saw is grounded to the ground wire inside the dust
collector hose.


Accuracy Issues

Small accuracy errors of 1/16” or less

• Be sure the jaws fit tight and flat when in use and when calibrating.
• Be sure the lock knob is tight.
• Check for loose or flexing brackets.
• Make sure that the scale is perpendicular to the table in all planes.


Large accuracy errors of .200” or more

• An error of exactly .200" is a very common error number with these devices or even a multiple of it

like .400, .600, 1.200 etc. Usually this only happens when the readout is either moved very quickly
(more than 3 feet per second) Follow the same steps outlined in the “Loses calibration” section
above.