Heater wiring, Figure 20 – State SBL95 250NE A User Manual

Page 22

Advertising
background image

22

heater wiring

All electrical work must be installed in accordance with the latest version of the National electrical Code ANSI/NFPA No. 70 and

must conform to all local code authority having jurisdiction. AN eleCTrICAl GrOUND IS reqUIreD TO reDUCe rISK OF

eleCTrICAl SHOCK Or POSSIble eleCTrOCUTION.
The controls of this water heater are polarity sensitive. be certain to properly wire the hot and neutral connections.

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED MUST BE REPLACED USE ONLY 18 AWG 105°C 600V UL AWM STYLE #1015 WIRE

EXCEPT GAS VALVE CABLE WHICH MUST USE 2 CONDUCTOR 18 AWG 80°C 300V UL CATAGORY QPTZ POWER LIMITED CIRCUIT CABLE.

BY INSTALLER

FACTORY INSTALLED

V1/

PV1

V2

GND

FC+

S1

IND/

MV1

TH/

W

FC-

LED

J5

5 1

6

3

J6

1

2

3

4

BLOWER

PRESSURE

SWITCH

FLAME

ROD

GAS

VALVE

SPARK

4
2

1

120VAC HOT
120VAC NUETRAL

EARTH GND

UPPER PROBE

LOWER PROBE

BLOWER

ON/OFF SWITCH

THERMOSTAT

EBM UGB

IGNITION MODULE

1a

1b

1

BK

BK

R
R

R

R

figure 20.

Advertising