Version — show firmware version, Wind_get — get calibration data, Configuration parameters – Vaisala WMT700 User Manual

Page 120

Advertising
background image

User's Guide ______________________________________________________________________

wind speed measurement unit, profile, baud rate, interface, and
analog output.

H

VERSION — Show Firmware Version

This command displays the label and version of the WMT700
software.

VERSION

WIND_GET — Get Calibration Data

This command fetches the WMT700 calibration date and other
calibration data. This information is mostly intended for Vaisala
technical support.

WIND_GET

Configuration Parameters

There are a number of parameters affecting WMT700
functionality. Appendix D, Configuration Parameters, on page
205 l
ists the parameters for configuring WMT700 settings. It
includes a detailed description of and the default values for each
parameter and the allowed values when using the WMT700
profile. Unless otherwise stated in the table, the changes take
place immediately after the command is sent.

To view and set parameter values, use the G and S commands.

NOTE

You can configure WMT700 by sending individual commands or by
loading a configuration file to the sensor. For instructions on configuring
all settings at once using configuration files, see section Loading Settings
from Configuration File on page 124.

For information on configurable parameters and allowed values
when using the WS425 and SDI-12 profiles, see section
Upgrading from WS425 to WMT700 on page 89.

NOTE

In the automatic message mode, to initiate continuous measurement, use
the START command. See section START — Start Continuous
Measurement on page 115.