Rs485 for com2 with cable 2 m and 10 m, Figure 35, Com2 rs485 wiring – Vaisala WMT700 User Manual

Page 81: Table 23

Advertising
background image

Chapter 4 ________________________________________________________________ Installation

RS485 for COM2 with Cable 2 m and 10 m

In RS485 mode, the same signals as in RS422 mode are available
at the end of Cable 2 m and Cable 10 m. Make two-wire loop-
backs at the end of the cable, as shown in Table 23 and Figure 35
below.

Table 23

COM2 RS485 Wiring

WMT700 Signals Wire Colors

Pin

RS485 Signals

RxB

Green

3

-

TxB

Yellow

4

TxA

Brown-Green

14

+

RxA

White-Yellow

15

1009-016

Figure 35

COM2 RS485 Wiring

NOTE

To avoid confusion, the RS485 and RS422 signals of WMT700 are
named as follows:
- Inverting: –
- Non-inverting: +

According to the EIA-485 standard, the lines are named as follows:
- Inverting: – <=> A
- Non-inverting: + <=> B

The A/B naming used by some manufacturers is in conflict with the
standard. To ensure proper operation, verify the polarity of the signals
when using the device on the bus with signals named as A/B. Opposite
polarity causes data inversion on the bus, but it does not damage the
device.

VAISALA ________________________________________________________________________ 79

Advertising