RAMP UP HIGH - Sets the time to ramp the output from low speed to high speed. This parameter applies only to

two-speed modes. The Ramp Up High parameter is variable.

RAMP DOWN HIGH - Sets the time to ramp the output from high speed to low speed. This parameter applies only

to two-speed modes. The Ramp Down High parameter is variable.

RAMP DOWN LOW - Sets the time to ramp the output from low speed to off. This parameter applies only to two-

speed modes. The Ramp Down Low parameter is variable.

OUTPUT CURRENT - Displays the present output current. This parameter is a monitor type.

SUPPLY VOLTAGE - Displays the

module’s power supply voltage. It is helpful for troubleshooting. This parameter

is a monitor type.

FAULT STATUS - The Fault LED displays solid red for faults: Open Output, Voltage Drop and Low

–10V Supply.