Physical description, User interface, Pv100 – High Country Tek ProValve 100 Series User Manual

Page 6: Valve controller

Advertising
background image

021-PV100 Rev A

PV100 User Manual

6

Copyright © High Country Tek, Inc.

– 2013

PV100

Valve Controller

Physical Description

The boxed numbers 1 to 16 represent the terminal positions. A label on the side
of the module provides a list of terminal functions.

There are four indicator LEDs.

The “POWER” LED is green when the applied voltage is within the operating
range.

The “OUTPUT A” and “OUTPUT B” LED’s are yellow and the brightness will
vary with the output current.

In the case of a fault,

the “FAULT” LED will display solid red until clearing faults

by moving the command signal out of the active range or cycling the power. See
Fault Status for details.

The PV100 communicates with the Graphical User Interface through the RJ-11
to DB9 convertor. It must be powered when configuring the settings.

User Interface

The PV100 has a number of internal settings.

Users can open the Graphical User Interface to view, make changes and save the settings in a data file which can
be uploaded to any PV100 controller.

The Hand Held Interface can also be used to view and make changes, but this device does not have the capability
to save the settings in a data file. The programmer, cable and adapter are self-contained which makes the HHI a
viable alternative for field work.

The following diagram shows the RJ-11 to DB9 converter pin-out:

Advertising