Vi-poscon installation guide – Videoswitch Vi-POSCON User Manual

Page 33

Advertising
background image

Videoswitch 33

Pos601a.doc

Vi-POSCON Installation Guide

passing data.

NOTE 2: It may be necessary to switch the printer interface into
Test Mode to perform diagnostics (refer to the Installation
Document for the printer interface, for switch setting details).

4. Data Cable between
Vi-POSCON controller

If data exists at the printer interface output, check the continuity of
the data cable between the Vi-POSCON and the printer interface
(refer to the Installation Document for the printer interface, for the
connection details).

5. Cable from the cash
register

If no data at the printer interface output;-

Check the connections between register and the printer interface
input (refer to the Installation Document for the printer interface,
for details).

Check to ensure that the correct printer interface has been
installed for the cash register.

If a 5001 Serial printer interface, check to ensure that the input
baud rate matches that of the register output baud rate (refer to
the Installation Document for the printer interface, for the input
baud rate switch settings).

6. Power to printer
interface

If still no data, check for either 12Vdc or 24Vac from the printer
interface power supply. If no 12Vdc or 24Vac, check input to the
transformer.