Switcher set operations (not vt-11) – Videoswitch VT User Manual

Page 11

Advertising
background image

VT Series 2

User Manual

Page 11

Videoswitch

VT601c.doc

6.

Switcher SET Operations (not VT-11)

The SET key is used to configure various aspects of the switcher. Note that the SET key lockout (section
8.5) must be turned off before any of these actions can be performed. When the keys are released after a
switcher related SET function, there should be two audible bleeps. An error condition is indicated by four
bleeps. If this occurs, repeat the setting.

6.1 Specify Cameras for Monitor A

The cameras which are included in an auto sequence are either determined by DIL switch settings, or are
programmed independently for each monitor using the SET key. Refer to section 8.1 to set the DIL switch
. If the programmable option is selected, then the required cameras are chosen as follows:

Press and hold the AUTO A key first, then press the SET key, then press various Monitor A camera keys
to toggle the LEDs on and off to select the cameras that you wish to be sequenced, then release all keys:

[AUTO A], [SET] and [Camera 1, 2, 3, 4, 5, 6, 7, 8]

6.2 Specify Cameras for Monitor B (VT-28A only)

The cameras which are included in an auto sequence are either determined by DIL switch settings, or are
programmed independently for each monitor using the SET key. Refer to section 8.1 to set the DIL switch
. If the programmable option is selected, then the required cameras are chosen as follows:

Press and hold the AUTO A key first, then press the SET key, then press various Monitor B camera keys
to toggle the LEDs on and off to select the cameras that you wish to be sequenced, then release all keys:

[AUTO B], [SET] and [Camera 1, 2, 3, 4, 5, 6, 7, 8]

6.3 Set Monitor A Dwell Time

To set the auto dwell time for monitor A, press and hold the “SET” key on, then press and hold the
“AUTO A” key on for the required dwell duration.

[SET] and [AUTO A]

The unit will beep every second. When the required number of seconds has elapsed, release both keys.

6.4 Set Monitor B Dwell Time (VT-28A only)

To set the auto sequence dwell time for monitor B, press and hold the “SET” key on, then press and hold
the “AUTO B” key on for the required dwell duration:

[SET] and [AUTO B]

The unit will beep every second. When the required number of seconds has elapsed, release both keys.

6.5 Set Alarm Hold Time

To set the Alarm Hold Time, press and hold the SET key and then also press and hold the Monitor A
Camera 1 key:

[SET] and [Camera 1]

Keep both keys held for the required duration. Every second the transmitter will bleep.

Advertising