DME Gate-Mate Nozzle User Manual

Gate-mate nozzle assemblies, Installation data, Jumbo gate-mate assembly

Advertising
background image

1.0625

±0.005

L (REF.)

B DIA.

0.250 *

D

A (REF.)

2.625

- 0.004

0.000

DIA.

0.562 REF.

JUMBO GATE-MATE ASSEMBLY

THERMOCOUPLE

HEATER AND THERMOCOUPLES LEADS

SQ. COIL HEATER

BOTTOM OUT COIL
HEATER ON NOZZLE

EXIT THRU SLOT IN NOZZLE BODY

NOZZLE

BODY

SEAL

BODY

RING

TIP SUB-ASSEMBLY

* DIMENSION INDICATES CORRECT HEATER DISTANCE.

1.5000

-0.004

0.000

DIA.

L (REF)

A (REF)

D

0.6250

B DIA.

0.200 *

MINI GAT-MATE SUB-ASSEMBLY

CAST-IN HEATER WITH INTERNAL
THERMOCOUPLE (SHOWN) OR SQUARE

TIP SUB ASSEMBLY

COIL HEATER AND THERMOCOUPLE

* DIMENSION INDICATES CORRECT HEATER DISTANCE

DANGER

WARNING

out residual moisture before applying full power. Failure to do so may cause

IMPORTANT SAFETY INFORMATION

A hot-runner system includes electrical elements and may contain molten
plastic at elevated temperature and pressure. To avoid injury, exercise
caution by reading these instructions before servicing or operating the
system.
These instructions must be passed on to the end user where they should
be read before using this product. Failure to do so can result in serious
injury or death.

Failure to comply can result in serious injury or death:
STORED ENERGY AND HIGH TEMPERATURE HAZARDS
This product maintains molten plastic at high pressure. Use caution when
operating and servicing the system.
Physical contact with molten plastic may result in severe burns. Proper
protective equipment, including eye protection, must be worn. This product
has heated surfaces. Use caution when operating and servicing the system
to avoid severe burns. Proper protective equipment should be worn.

Failure to comply will result in serious injury or death:
ELECTRICAL HAZARDS
Improper voltages or grounding can result in electrical shock. Use only
with proper voltage and a proper earth ground.
To avoid electrical shock, do not operate product when wet.
Do not operate this equipment with covers or panels removed.
To avoid electrical shock, turn off main power disconnect and lockout /
tag out before servicing this device. Do not connect temperature sensors to
electrical power. It will damage the product and it can cause fire, severe
injuries or even death.
If green ground wire present wire must be connected to the ground.
Do not rebend rigid leads. Rebending leads might result in damage to circuit.
Product might absorb moisture when cool. Use low Voltage or power to drive

damage to this product.

PURPOSE. IN NO EVENT SHALL D-M-E BE RESPONSIBLE FOR LOSS OF USE, REVENUE

D-M-E SHALL NOT BE LIABLE FOR MISUSE OR FAILURE TO FOLLOW THE ENCLOSED
INSTRUCTIONS AND SPECIFICATIONS. D-M-E HERBY TO DISCLAIMS ALL IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR

OR PROFIT, OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGED.

Note: Dimensions shown in Inches.

ME-0739-PS-310-D

09-08

NOZZLE

dropped or strikes a rigid material.Treat tip like a glass or ceramic material.

the gate may have to be enlarged to achieve greater flow. This increase in

3. Do NOT

2.000

lubricate or use anti-seize compound on the threads.

2. Careful attention should be taken to the tip as damage could occur if tip is

seal-off area and threaded areas before reassembling.

1.375

the cavity at processing temperature.The smallest gate diameter will yield

1.645

NUMBER

MINI

GMB0110

GATE-MATE NOZZLE ASSEMBLIES

GMB9999

SQ. COIL

4.562

DIM.

1. Nozzle (multiple-applications) body must be cleaned of any material in the

RECOMMENDATIONS AND GUIDELINES

B

2.500 + BE (NOT 2.460 + BE) using the GMT0007 tip. For best

0.6250

DIA.

deep, to fit the nozzle's head.

8. Machine the "B" diameter + 0.0005 -0.0000 directly into the cavity carefully,
as this is a seal-off dimension to fit the nozzle's seat.

9. For best processing and lowest gate vestige, tip must be 0.000 to 0.005 into

D

+0.001/-0.000 directly into the nozzle plate, 0.250 minimum to 0.750 maximum

CATALOG

GMB0120

diameter may result in a larger gate vestige.

heat to transfer into the tip before molding.

DIM.

HEATER

STYLE

JUMBO

head. For the Jumbo Gate-Mate nozzle, machine the 2.626 diameter

7. For the Mini Gate-Mate nozzle. machine the 1.501 +0.001 -0.000 directly into
the nozzle plate, 0.125 minimum to 0.375 maximum deep, to fit the nozzle's

13. Wait a minimum of 5 minutes after set point has been achieved for sufficient

10. Provide maximum water cooling in the nozzle plate and in cavity insert around

1.094

the best gate vestige.Depending on part configuration and plastic being used,

CAST-IN

GMB0118

INSTALLATION DATA

Please read carefully before installing components.

STYLE

A

12. Provide a gate dimple on core/cavity opposite gate. This will allow for best

DIM.

L

4. Tip must be torque into the nozzle body using a torque wrench at 20 to
25 ft-lbs for the GMT0101 and GMT0006 wear resistant tips, and 35 5 ft-lbs.
for all other tips when reassembling. For protection of the tip point, use a
9 mm deep well 6 point thin wall socket for the Mini, and 17 mm deep well

11. Route wires through wire channel in nozzle plate.

6 point socket for the jumbo.

5. Careful attention should be taken to the heater and thermocouple leads as
damage could occur when working on nozzle assembly.

6. Seal ring for nozzle body must be replaced each time nozzle body and / or
manifold are removed to ensure seal off.

3.500

plate.

material flow.

1.2500

be a direct replacement for the jumbo tip.Given a "A" dimension of

GMT0007 thru hole tip. This tip was designed 0.040 shorter in length to

is recommended.

14. Use the GMT0004 jumbo tip machining dimensions when using the

2.645

SQ. COIL

GMB0119

3.562

2.500

processing and lowest gate vestiage a 0.080 to 0.125 diameter gate

Advertising