PACKET-7

Command Name

Short

Description

Parameter

Default

TRFLOW

TRF

When ON, causes the TNC to respond to software
flow control from the computer in Transparent mode.

ON/ OFF

OFF

TRIES

TRI

Specifies the number of transmission retries
programmed in the retry counter.

0 ~ 15

0

TXDELAY

TX

Specifies the time delay between PTT ON and start
of transmission. The unit of the parameter is 10
milliseconds.

0 ~ 120

50

TXFLOW

TXF

When ON, allows the TNC to send a software
flow control (XON and XOFF) to the computer in
Transparent mode.

ON/ OFF

OFF

UICHECK

UIC

Does not forward the same UI packet as one received
within the time specified by this command. The unit of
the parameter is 1 second.

0 ~ 250

28

UIDIGI

UI

When receiving a UI packet which includes the
parameter specified by this command, replaces the
parameter with the MYCALL parameter and forwards
the packet.

OFF/

ON Call1, ...

call14

OFF

UIDWAIT

UIDW

When ON and digipeating, causes the TNC to use the
DWAIT and PPERSIST settings.

ON/ OFF

OFF

UIFLOOD

UIF

Specifies how received UI packets, which include
WIDEN-N or TRACEN-N parameters, are processed.
Enter WIDE or TRACE before ID, NOID, or FIRST; ex.
WIDE,FIRST. With ID selected, deletes the relayed
digipeaters and adds the MYCALL parameter. With
NOID, merely decrements N-N; ex. 4-3 to 4-2. With
FIRST, adds the MYCALL parameter only when
serving as the first digipeater.

ID/ NOID/ FIRST

ID

UISSID

UIS

When ON, causes the TNC to process received UI
packets depending on included destination SSIDs.

ON/ OFF

OFF

UITRACE

UIT

The command name must be followed by up to 5
alphanumeric characters; normally WIDE or TRACE.
Causes the TNC to forward received UI packets which
include WIDEN-N or TRACEN-N parameters.

UNPROTO

U

Specifies call signs to send a packet in Unprotocol
mode. Call1 is the call sign of the destination. Call2
to call9 are call signs of stations to be digipeated
through.

Call1 (VIA call2,

call3

CQ

USERS

US

Specifies the number of channels available to connect
requests.

0 ~ 10

1

WRITE

W

Allows the TNC mailbox to store your message.
In order to permit only a specific station to read
your message, enter a call sign after the command
name; ex. W JA1YKX. To complete message entry,
press [Enter] (or [Return]), [Ctrl]+[C], then [Enter]
(or [Return]). For a subject, you can enter up to 30
alphanumeric characters.

XFLOW

X

Causes the TNC to perform software flow control when
ON, or hardware flow control when OFF.

ON/ OFF

ON