Rear connection – Town RiceMaster Gas Rice Cookers User Manual
Page 5

5
RM-55 REAR CONNECTION INSTALLATION INSTRUCTIONS
To install the provided pressure regulator:
a. Locate gas supply for the rice cooker. Installation must comply with the National codes so
there should be a shut off valve on the gas supply line to the rice cooker.
b. Install the supplied pressure regulator at the end of the rear connection manifold. An arrow
on the body of the pressure regulator indicates the direction of the gas flow. The arrow must
be pointing in the direction to the rice cooker. The rice cooker will not operate if the
regulator is improperly installed.
c. If required, install the supply side of the quick disconnect hose (provided by others) to the
regulator per the manufacturer’s instructions.
d.
Check your installation for leaks with an approved leak detector. Be sure to use approved
materials on the pipe threads to prevent gas leaks.
When appropriate, light the rice cooker and check for proper operation.
(718) 388-5650 (800) 221-5032 except NY fax: (718) 388-5860 townfood.com
PRESSURE
REGULATOR
REAR CONNECTION