Instruc

tions manual - English - EN

13

MNVCUCHD_1405_EN

6.1.4 Connection of the secondary

connector board

6.1.4.1 Board description

BOARD DESCRIPTION

Connector

Function

J1

Ethernet Connector

J4

Alarm and relay connector

Tab. 3

J4

J1

Fig. 10 Alarms, relay and HD IP video output board.

6.1.4.2 Connection of the alarm inputs

In case of free contact alarm make the connection as

shown in the figure.
The alarm contacts are present on the connector J4.

A

G

Dry contact

Fig. 11

The clean contact alarm can be NO (normally open)

or NC (normally closed).
For further details on configuring and using the

alarms, refer to the related chapter (8.2.10 Digital I/O,

page 24).

CONNECTION OF THE ALARM INPUTS, OF THE

TWILIGHT SWITCH AND OF THE RELAYS

Terminal

Description

A, G

Self-powered alarm input referred to G

Tab. 4

All alarms have an approximate reach of 200m, which

can be obtained using an unshielded cable with a

minimum section of 0.25mm² (AWG 24).