• This device was designed to be permanently

installed on a building or on a suitable structure.

The device must be installed permanently before

any operation.

• Installation category (also called Overvoltage

Category) specifies the level of mains voltage

surges that the equipment will be subjected to.

The category depends upon the location of the

equipment, and on any external surge protection

provided. Equipment in an industrial environment,

directly connected to major feeders/short branch

circuits, is subjected to Installation Category III. If

this is the case, a reduction to Installation Category

II is required. This can be achieved by use of an

insulating transformer with an earthed screen

between primary and secondary, or by fitting

listed Surge Protective Devices (SPDs) from live

to neutral and from neutral to earth. Listed SPDs

shall be designed for repeated limiting of transient

voltage surges, suitable rated for operating voltage

and designated as follows: Type 2 (Permanently

connected SPDs intended for installation on the

load side of the service equipment overcurrent

device); Nominal Discharge Current (In) 20kA min.

For example: FERRAZ SHAWMUT, STT2240SPG-CN,

STT2BL240SPG-CN rated 120/240Vac, (In=20kA).

Maximum distance between installation and

reduction is 5m.

• Use a Class 2 listed UL tranformer, compliant with

the Standards in force, only for products marked

UL, powered at 24Vac.

• A disconnecting device, readily and easily

accessible, must be incorporated in the electrical

system of the building for rapid intervention.

• The separate protective earthing terminal provided

on this product shall be permanently connected

to earth.

• For continued protection against risk of fire,

replace only with same type and rating of fuse.

Fuses must be replaced only by service personnel.

• The installation is type TNV-1, do not connect it to

SELV circuits.

• In order to reduce the risk of fire, only use UL Listed

or CSA certified telecommunication line cord sizes

greater than or equal to 26AWG.

• Hazardous moving parts. Keep fingers and other

body parts away.

• Connect the device to a power source

corresponding to the indications given on the

marking label. Before proceeding with installation

make sure that the power line is properly isolated.

The supply voltage should never exceed the limit

(+/-10%).

• The electrical system to which the unit is

connected must be equipped with a 20A max

automatic bipolar circuit breaker. The minimum

distance between the contacts must be 3mm

(0.1in). The circuit breaker must be provided

with protection against the fault current towards

the ground (differential) and the overcurrent

(magnetothermal).

• If it is necessary to transport the device, this should

be done with great care. Abrupt stops, bumps and

violent impact could damage the unit or injure the

user.

• To comply with the main supply voltage dips and

short interruption requirements, use a suitable

Uninterruptable Power Supply (UPS) to power the

unit.