Section 6. Keys Received From Device


77

MICRChkType

This key specifies the check type based on the presence on the Auxiliary On-Us MICR field. This key is
supported by Excella and Excella STX.

Values

Value Description

PERSONAL

Auxiliary On-Us MICR field NOT present

BUSINESS

Auxiliary On-Us MICR field present

MICRCountry

This key specifies the country of origin based on known MICR line formats. This key is supported by
Excella and Excella STX.

Values

Value Description

USA

Check drawn in USA

CANADIAN

Check drawn in Canada

MEXICAN

Check drawn in Mexico

MICRDecode

This key indicates whether a MICR decode/read error was detected. This key is supported by Excella and
Excella STX.

Values

Value Description

NONE

No MICR data detected

OK

MICR decode/read was successful

ERROR

Error detected in MICR decode/read operation

MICREPC

This key specifies the EPC MICR field read from the check. This key is supported by Excella and Excella
STX.

Values

Value Description

string

EPC MICR field

MICROnUs

This key specifies the On-Us MICR field read from the check. This key is supported by Excella and
Excella STX.

Values

Value Description

string

On-Us MICR field