Excella Windows API Specifications

80

MICRParseSts1

This key specifies a 2-digit status/error code reported by the device after parsing the MICR fields read
from the check. This key is supported by Excella and Excella STX.

Values

Value Description

numeric value

For specific status/error code information refer to table 6-10

Table 6-10. MICRPARSESTS1

PRIORITY MICRParseSts1

TYPE

DESCRIPTION

10

01

Error

No MICR data: no transit and no account found

9

09

Status

Mexican check

8

08

Status

Canadian check

7

05

Error

No transit, bad character, bad length, bad check digit

6

07

Error

No account, bad character

5

04

Error

Bad character in check number

5

04

Status

No check number

4

12

Status

Short Account (maybe caused by mis-parsed check#)

3

03

Status

Low MICR signal, good read

2

10

Status

Business check

1

11

Status

Amount field present

0

00

Status

No error, check OK

Notes:

The LED indicator will turn red on all error conditions.

The absence of a check number is not considered an error.

If a multiple error occurs, the error or status code with the highest priority is reported.

All unreadable MICR characters are transmitted as an “?” ASCII character (hex 3F), except for Format 00xx.


Advertising