3 - Preventive Maintenance Procedure

ExpressCard 2000| Instant Issuance Card Personalization System | Preventive Maintenance Procedure


Page 13

Figure 3-7 - Run a Thin Bead of Tri-Flow Along the Top of the Shaft (TOP LEFT VIEW)

7) Use the drive belt to move the XY transport to the front of the device, then to the rear again to spread

the Tri-Flow along the length of the shaft.

8) If you have applied too much Tri-Flow to the shaft, some may drip off the shaft. If this happens, dab

off the excess with a clean, lint free cloth.

3.8 Power Down the Device / Cool the Tipper Heater

1) Navigate to

Menu

>

Settings

>

Tipper

to open the

Tipper

page.

2) Press the

Set Heater OFF

button to turn off the tipper heater.

3) Note the value under Current Tipper Temp. If the tipper temperature is 50 degrees Centigrade or

hotter, the tipper heater is not safe to touch.

4) Take note of the current time, and plan your work to allow enough time for the tipper heater to cool,

which can take up to 15 minutes. You may be able to use compressed air to cool it more quickly.

5) Power down the device.