Section 3. Operation

11

Table 3-1. Communication Setup

Bit value in [Y]

P 6 5 4 3 2 1 0

Field

. . . . . .

0

0

Baud Rate:
1200

. . . . . . 0 1

2400

. . . . . . 1 0

4800

. . . . . . 1 1

9600

. . . .

0

0

.

.

Parity:
Odd

. . . . 0 1 . . Even
. . . . 1 0 . . Mark
. . . . 1 1 . . Space
. . .

0

. . . . BCC:

Don’t Use

. . . 1 . . . .

Use

0

0

Always

zero

x

Parity

Bit

x =the parity bit (not included in the byte)

Note

On all requests and responses, {BCC} is present only if enabled.


The “S” command will set MT-85 communication parameters.

Request:

1 2

3

4 5 6

<STX> <ESC> S

[Y]

<ETX>

*

*BCC is ignored in this command, even if enabled.

Response:

1 2

3

4 5 6

<STX> <ESC> S

[Y]

<ETX> {BCC}



[Y] is defined in Table 3-1, above.