Section 3. Operation
11
Table 3-1. Communication Setup
Bit value in [Y]
P 6 5 4 3 2 1 0
Field
. . . . . .
0
0
Baud Rate:
1200
. . . . . . 0 1
2400
. . . . . . 1 0
4800
. . . . . . 1 1
9600
. . . .
0
0
.
.
Parity:
Odd
. . . . 0 1 . . Even
. . . . 1 0 . . Mark
. . . . 1 1 . . Space
. . .
0
. . . . BCC:
Don’t Use
. . . 1 . . . .
Use
0
0
Always
zero
x
Parity
Bit
x =the parity bit (not included in the byte)
Note
On all requests and responses, {BCC} is present only if enabled.
The “S” command will set MT-85 communication parameters.
Request:
1 2
3
4 5 6
<STX> <ESC> S
[Y]
<ETX>
*
*BCC is ignored in this command, even if enabled.
Response:
1 2
3
4 5 6
<STX> <ESC> S
[Y]
<ETX> {BCC}
[Y] is defined in Table 3-1, above.