Section 3. Transport Frame Types


13

Resynchronize Protocol Command

Command Code:
0 (0000)

S-frame Type: Request/Response

Request PCB: 90 (Hex)

Response PCB: A0 (hex)


Description:

This request is used to resynchronize the protocol as part of error recovery (e. g., unrecoverable
sequence errors, retries exceeded, etc.). The transport may also use this at the beginning of the
session to initialize the sequence numbers of the device.

The recipient of this request must do each of the following:

set their next expected sequence number (N(R)) to zero

set their send sequence number (N(S)) to zero

discard any previously sent frames that may be buffered

respond with a resynchronize protocol response (same as the request except the S-
frame type is response)

Request Data: None

Response Data:

Result Code

Result Codes:

Success = 00 (Hex)

This command should always succeed.