Section 3. Transport Frame Types


17

Set Communication Parameters Command

Command Code: 3 (0011)

S-frame Type: Request/Response

Request PCB: 93 (Hex)

Response PCB: A3 (hex)

Description:

This command sets the value of one of the devices communication parameters.

Request Data:

Parameter ID

Value

Response Data:

Result Code

Block Wait Timeout (BWT) Parameter

Parameter ID: 04 (Hex)

Description:

This parameter is used to set the block wait timeout value the device is using.

Value:

The value of this parameter is a one byte field that can be in the range of 25 to 250. The actual
value of the block wait timeout is the value of this field multiplied by 10ms. For example, if the
value of this field is 25 (19 hex) the block wait timeout is 25 times 10ms which equals 250ms.
This parameter defaults to a value of 25 (250ms) after a power cycle or a reset.

Result Codes:

Success = 00 (Hex)

The command always completes successfully.