Ss tk2 7bits property, Ss tk3 iso aba property, Ss tk3 aamva property – MagTek USB INSERTION READER User Manual

Page 49

Advertising
background image

Section 5. USB Communications (KB)

41


c

1-127 – 7 bit ASCII char code

0 – send nothing

This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


SS TK2 7BITS PROPERTY

Property ID:

6

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x40 ‘@’

Description:

This character is sent as the track 2 start sentinel for cards that have track 2
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


SS TK3 ISO ABA PROPERTY

Property ID:

8

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x2B ‘+’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


SS TK3 AAMVA PROPERTY

Property ID:

9

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes