Es tk2 property, Es tk3 property – MagTek USB INSERTION READER User Manual

Page 60

Advertising
background image

USB Insertion Reader

52

Get Property:

Yes

Set Property:

Yes

Default Value:

0xFF (use ES property)

Description:

This character is sent as the end sentinel for track 1 with any format. If the
value is 0 no character is sent. If the value is in the range 1 – 127 then the
equivalent ASCII character will be sent. If the value is 0xFF then the value of
the ES property will be used instead of this property.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


ES TK2 PROPERTY

Property ID:

24 (0x18)

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0xFF (use ES property)

Description:

This character is sent as the end sentinel for track 2 with any format. If the
value is 0 no character is sent. If the value is in the range 1 – 127 then the
equivalent ASCII character will be sent. If the value is 0xFF then the value of
the ES property will be used instead of this property.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


ES TK3 PROPERTY

Property ID:

25 (0x19)

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0xFF (use ES property)

Description:

This character is sent as the end sentinel for track 3 with any format. If the
value is 0 no character is sent. If the value is in the range 1 – 127 then the
equivalent ASCII character will be sent. If the value is 0xFF then the value of
the ES property will be used instead of this property.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.

Advertising