Reader installation – MagTek MT-211232 RS-232 1 OR 2 TRACK User Manual

Page 22

Advertising
background image

MT-211 RS-232 Swipe Reader, 1 or 2 Tracks


14

Switch B2:

This switch sets the operating mode (BUFFERED or UNBUFFERED). Switch 2
should be set to the ON position for the buffered mode. Switch 2 should be set to
the OFF position for the unbuffered mode.

Switch B3:

This switch is factory set to OFF and should not be changed.


Switch B4:

This switch is factory set to ON for ESC I and ESC R Commands (See Section 3
for a description of these commands).


Switch B5:

This switch is factory set to ON and must not be changed.


Switch B6:

This switch is factory set to OFF and should not be changed.


Switch B7:

In the ON position, this switch jumpers the REQUEST TO SEND (RTS) and
CLEAR TO SEND (CTS) control signals together.


Switch B8:

In the ON position, this switch jumpers the DATA TERMINAL READY (DTR)
and DATA SET READY (DSR) control signals together. If the host is going to
implement the DATA SET READY (DSR) control signal, this switch should be
set to the OFF position.


READER INSTALLATION

Install the Reader as follows:

1.

Connect the serial cable from the Reader to the adapter cable and the adapter cable to the
PC serial port.


2.

Turn on power to the computer.


3.

Open Procomm, HyperTerminal (described below), or other communication program.


4.

Connect the power adapter 3.5 mm Mono plug to the Reader jack, and plug the adapter
into a 120 VAC wall socket. The green LED on the Reader should light; if it does not,
recheck the cable connections, check switches B7 and B8, and if necessary, notify
technical personnel.


5.

Ensure the switch settings on the Reader match those on the PC communications port. If,
for example, the values set in the Reader switches are baud rate 9600, parity Even, 7 data
bits, and 1 stop bit, the PC port should match these values (see HyperTerminal Setup
below).