Ss tk2 iso aba property, Es property, Es tk1 property – MagTek USB KB INTELLIHEAD User Manual

Page 37

Advertising
background image

Section 4. USB Communications

29

SS TK2 ISO ABA PROPERTY
Property ID:

0x15

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x3B ‘;’

Description:

This character is sent as the track 2 start sentinel for cards that have track 2
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


ES PROPERTY
Property ID:

0x16

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x3F ‘?’

Description:

This character is sent as the end sentinel for all tracks with any format except
JIS type 2. If the value is 0 no character is sent. If the value is in the range 1
– 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


ES TK1 PROPERTY
Property ID:

0x17

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0xFF (use ES property)

Description:

This character is sent as the end sentinel for track 1 with any format. If the
value is 0 no character is sent. If the value is in the range 1 – 127 then the
equivalent ASCII character will be sent. If the value is 0xFF then the value of
the ES property will be used instead of this property. This property was not
present until firmware revision with software ID 21042812H01.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.

Advertising