MagTek USB KB INTELLIHEAD User Manual

Page 41

Advertising
background image

Section 4. USB Communications

33


If only Track 2 is available:
<PAN><TAB><TAB><MM><TAB><YY><Termination Character>

If Track 1 and Track 2 are not in financial data format or cannot be decoded,
the reader will revert back to standard mode.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.

Rules used for determining that a card is in financial data format:
• PAN length should be between 13 and 19

• Name length should be between 0 and 26 characters for Track 1

• Only 2 field separators (‘^’) for Track 1

• Only 1 field separator (‘=’) for Track 2
• Format code shall be the character ‘B’ for Track 1

Example Set PAN Name Date Enable property to 01 Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

02

1D

01

Example Set PAN Name Date Enable property Response (Hex):

Result Code

Data Len

Data

00

00

Example Get PAN Name Date Enable property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1D

Example Get PAN Name Date Enable property Response (Hex):

Result Code

Data Len Prp Value

00

01

01

*This property was not added until firmware version 21042812L02.