Swb parameters, Control characters and micr data, Table 4-2. swb command – MagTek MICR Plus RS-232 User Manual

Page 21

Advertising
background image

Section 4. Commands

13

Table 4-2. SWB Command

BIT FUNCTION

7

6

5

4

3

2

1

0

0

<LF>:

No

1

<LF>:

Yes

0

<CR>: No

1

<CR>: Yes

0

<ETX>: No

1

<ETX>: Yes

0

<ESC>: No

1

<ESC>: Yes

0

<STX>: No

1

<STX>: Yes

0

Send Data After Error?: No

1

Send Data After Error?: Yes

0

Send Status After Data?: No

1

Send Status After Data?: Yes

0

0

0

0

0

0

0

0

Comm Mode: 0 - Data Only

1

0

0

0

0

0

0

0

Comm Mode: 1 - Data <CR>

0

0

0

0

0

0

0

1

Comm Mode: 2 - Data -<LF>

0

0

0

0

0

0

1

1

Comm Mode: 3 - Data -<CR><LF>

0

0

0

0

1

0

0

0

Comm Mode: 4 - <ESC> Data

0

0

0

0

1

0

1

0

Comm Mode: 5 - <ESC> Data<CR>

0

0

0

1

0

1

0

0

Comm Mode: 6 - <STX> Data<ETX>

1

0

0

0

0

0

0

1

Comm Mode: 7 - Packet Mode
(<STX>Data<ETX><LRC>)

SWB PARAMETERS

The SWB functions are listed in Table 4-2 and described below.

Control Characters and MICR Data

Control Characters may be added to the MICR data message. The characters are always in the
following locations:

<STX> <ESC> data <ETX> <CR> <LF>


The control characters, descriptions, and hex values are shown in Table 4-3.