MagTek MICR Plus RS-232 User Manual

Page 42

Advertising
background image

MICR PLUS, RS-232

34


Fmt 52xx:

'T' [transit] 'T' [acct #] 'A' [check #]


• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- all characters in the field

- remove dashes and spaces


Fmt 53xx:

'/' [transit] '/' [acct #] '/' [check #] '/' [tpc] '/' [status] '/'


• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- all characters in the field


• [tpc]:

- all characters in the field


• [status]:

- this is a programmable option that must be enabled (See Table 4-4)


Fmt 54xx:

[transit] [acct #] [check #] [status]


• [transit]:

- always 12 characters, zero filled

-

remove

dashes


• [acct #]:

- always xx characters, zero filled;

when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- always 12 characters, zero filled

- remove dashes and spaces


• [status]:

- this is a programmable option that must be enabled (See Table 4-4)


Fmt 55xx:

'C' '/' [acct #] '/' [transit] '/' [check #] '/' 0000000000


• [acct #]:

- always xx characters, zero filled;

when xx=00 all characters are sent

- remove spaces and dashes


• [transit]:

- all characters in the field

-

remove

dashes


• [check #]:

- always 6 characters, zero filled

- remove dashes and spaces

Advertising