Section 4. Commands

15

Send Status After Data

The Send Status After Data option makes the MICR Plus append a two-digit error/status code to
the end of the MICR data. For most formats (See Appendix A) the error/status code will always
be preceded by a forward slash (/). The error/status codes are listed in Table 4-4.

For example, if a Canadian check (code 08) is read and had no errors, and the MICR data is
“1234567890”, then the message from the MICR Plus will look like this:

MICR Data: 1234567890/08


The status code is always at the end of the data, not the end of the message. For example, using
the above conditions, with the message format set to send <STX> and <ETX>, the message from
the MICR Plus will look like this:

MICR Data: <STX>1234567890/08<ETX>

Table 4-4. Error and Status Codes

PRIORITY CODE

TYPE

DESCRIPTION

9

01

Error

No MICR data: no transit and no account found

8 09

Status

Mexican

check

7 08

Status

Canadian

check

6

05

Error

Transit error: No transit, bad character, bad length,
bad check digit

5

07

Error

Account error No account, bad character

4

04

Error

Check # error: Bad character in check number

6

05

Error

No transit, bad character, bad length, bad check digit

5

07

Error

No account, bad character

4

04

Error

Bad character in check number

4

04

Status

No check number

3

03

Status

Low MICR signal, good read

2 10

Status

Business

check

1

11

Status

Amount field present

0

00

Status

No error, check OK

Notes:

•

The LED indicator will turn red on all error conditions.

•

The absence of a check number is not considered an error.

•

If a multiple error occurs, the error or status code with the highest priority is reported.

•

All unreadable MICR characters are transmitted as an “?” ASCII character (hex 3F), except for
Format 00xx (See Appendix A).