8471 34

NOTE: If burner is over 4′, natural gas, or 5′, propane gas, a back inlet is required as shown
below.

Gas

Inlet

Capacities

Maximum Feet of Burner

Inlet Size

Natural Propane

1.5 ″ NPT End Inlet

4′

5′

2″ NPT Back Inlet

6.5′

8′

Centrally Located

___________________________________


The performance of the HMA-2 & 2A burner depends on the unit in which the burner is located. The
burner can perform differently in different units and can obtain different end results. Maintaining a
relative laminar fl ow around the burner and providing a suffi cient space between the burner and
the blower is a key factor in obtaining best burner performance. The unit should be free of any
obstructions that can create turbulent effect on the air.

Note: Any reinforcements around the profi le plates should be down stream of the profi le plate.

Static pressure probes are needed to sense the differential air pressure across the profi le plates.
The static pressure probes should be installed 12″ upstream from the burner and 12″ downstream
from the burner centrally located in the duct. See Figure 1a and 1b for typical location.

Burner Assembly

Burner Placement
in the Profi le

Installation

Air Flow

Adjustable
Profile Plate

Fixed
Profile Plate

Profile
Opening
should be
Centered to
the Burner

Burner should
be Centered
to the Blower

12"

12"

Static
Pressure
Probe

Static
Pressure
Probe

1" to 4", typical 2"

Air Flow

Burner should
be Centered
to the Blower

4"

4"

Figure 1b - Burner Placement in the Profi le

Figure 1a - Burner Placement in the Profi le

Table 4 - Gas Inlet Capacities