Important safety information 2, Important electrical information, English – Wagner ProCoat 9195 User Manual

Page 3

Advertising
background image

English

3

9. This system is capable of producing 2800 PSI / 193 Bar

(9145) or 3000 PSI / 207 Bar (9155/9175/9195). Only

use replacement parts or accessories that are specified

by the manufacturer and that are rated a minimum of

3000 PSI. This includes spray tips, nozzle guards,

guns, extensions, fittings, and hose.

10. Always engage the trigger lock when not spraying.

Verify the trigger lock is functioning properly.

11. Verify that all connections are secure before operating

the unit.

12. Know how to stop the unit and bleed pressure quickly.

Be thoroughly familiar with the controls. Pressure will

not be released by turning off the motor. The PRIME/

SPRAY valve or pressure bleed valve must be turned to

their appropriate positions to relieve system pressure.

Refer to PRESSURE RELIEF PROCEDURE described

in the pump manual.

13. Always remove the spray tip before flushing or cleaning

the system.

nOTE TO PHYSICIan:

Injection into the skin is a traumatic injury. It is

important to treat the injury as soon as possible. DO

NOT delay treatment to research toxicity. Toxicity is a

concern with some coatings injected directly into the

blood stream. Consultation with a plastic surgeon or

reconstructive hand surgeon may be advisable.

d) WaRnIng - To reduce the risk of injury:

1. Always wear appropriate gloves, eye protection,

clothing and a respirator or mask when painting.

Hazardous vapors – Paints, solvents, insecticides, and

other materials can be harmful if inhaled or come in

contact with body. Vapors can cause severe nausea,

fainting or poisoning.

2. Do not operate or spray near children. Keep children

away from equipment at all times.

3. Do not overreach or stand on an unstable support.

Keep effective footing and balance at all times.

4. Stay alert and watch what you are doing.

5. Do not operate the unit when fatigued or under the

influence of drugs or alcohol.

6. Do not kink or over-bend the hose. Airless hose can

develop leaks from wear, kinking and abuse. A leak

can inject material into the skin.

7. Do not expose the hose to temperatures or pressures in

excess of those specified by manufacturer.

8. Do not use the hose as a strength member to pull or lift

the equipment.

9. Use lowest possible pressure to flush equipment.

10. Follow all appropriate local, state and national codes

governing ventilation, fire prevention and operation.

11. The United States Government Safety Standards

have been adopted under the Occupational

Safety and Health Act (OSHA). These standards,

particularly part 1910 of the General Standards and

part 1926 of the Construction Standards should be

consulted.

12. Before each use, check all hoses for cuts, leaks,

abrasion or bulging of cover. Check for damage or

movement of couplings. Immediately replace hose

if any of those conditions exist. Never repair a paint

hose. Replace with a conductive high-pressure

hose.

13. Do not spray outdoors on windy days.

14. Always unplug cord from outlet before working on

equipment (electric models only).

Important Electrical Information

ImPORTanT: Use only a 3-wire extension cord that

has a 3-blade grounding plug and a 3-slot receptacle

that will accept the plug on the product. make sure

your extension cord is in good condition. When

using an extension cord, be sure to use one heavy

enough to carry the current your product will draw.

an undersized cord will cause a drop in line voltage

resulting in loss of power and overheating. a 14

or 12 gauge cord is recommended (see chart). If

an extension cord is to be used outdoors, it must

be marked with the suffix W-A after the cord type

designation. For example, a designation of SJTW-A

would indicate that the cord would be appropriate

for outdoor use.

Cord gauge

Maximum cord length

12

150 feet

14

100 feet

Do not use more than 100 feet of spray hose. If you

need to spray further than 100 feet from your power

source, use more extension cord, not more spray

hose.

If you experience problems with your sprayer at

any time during assembly, operation, or cleanup,

please refer to the Troubleshooting section of this

manual (page 22), or call customer service at:

1-800-880-0993

Specifications:

Capacity:

9145........... Up to .29 gallon (1.10 liter) / min

9155........... Up to .33 gallon (1.25 liter) / min

9175........... Up to .38 gallon (1.40 liter) / min

9195........... Up to .42 gallon (1.60 liter) / min
Power source:

9145........... 1/2 Hp universal motor

9155........... 5/8 Hp universal motor

9175........... 3/4 Hp permanent magnet DC motor

9195 .......... 7/8 Hp permanent magnet DC motor
Power requirement: 15 amp minimum circuit on 115

VAC, 60 Hz current

generator power requirement: 5000 Watt

Advertising